Troubleshooting NAS RAID Rebuild Failures
RAID helps protect your NAS data from drive failure by mirroring data or spreading it across multiple drives with parity. In most common NAS RAID levels (such as RAID 1, 5, 6, or 10), your files can survive at least one drive failure. When a drive dies, the system rebuilds the array onto a replacement drive to restore redundancy. Sometimes that rebuild fails—because of bad hardware, configuration or firmware issues, or power interruptions. The sooner you act, the better your chances of avoiding data loss.

Key Takeaways:
- RAID rebuilds fail due to faulty replacement drives, configuration errors, power interruptions, multiple drive failures, or outdated firmware.
- Troubleshooting involves verifying drive compatibility, running S.M.A.R.T. tests, stabilizing power and thermals, reducing system load, and updating NAS firmware before retrying the rebuild.
- RAID is not a backup; follow the 3-2-1 rule (three copies, two storage types, one off-site) and schedule regular data scrubs and health checks to prevent future failures.
- If a rebuild cannot complete, third-party recovery tools like EaseUS or Stellar can virtually reconstruct the array—avoid writing to the disks until you have a recovery plan.
Understanding a RAID Rebuild
When a drive fails, the NAS pulls data from the healthy drives, calculates what is missing, and writes it to the replacement drive. This is resource-intensive. Large arrays can take many hours or even days to rebuild. During that time the NAS may feel slower, and the array is more vulnerable until the rebuild completes.
If you’re rebuilding after a failure, it’s worth replacing the drive as soon as possible and keeping other heavy tasks to a minimum until the array is healthy again. For a step-by-step walkthrough, follow our guide on replacing a failed drive in a UGREEN NAS.

Common Causes of NAS RAID Rebuild Failures
Faulty or incompatible drives
A replacement drive that is defective, the wrong capacity, or not on the Supplier compatibility list can block or stall a rebuild. Very old drives may also fail to meet current NAS requirements.
RAID controller or configuration issues
Incorrect RAID level, drive order, or controller settings can derail a rebuild. Firmware bugs on the NAS or the drives can throw errors. Forgetting to mark a new drive as a hot spare or add it to the pool will prevent a rebuild from starting.
Multiple drive failures
Arrays like RAID 5 tolerate only one failed drive at a time. If another drive fails or throws an unrecoverable read error during the rebuild, the process can fail and data may be lost. Larger, older, or heavily used disks have a higher chance of read errors during long rebuilds.
Power failures and interruptions
Outages or unstable power can stop a rebuild mid-process and may corrupt data in flight. For NAS users in areas prone to grid interruptions, a dedicated NAS backup power supply can provide enough runtime to safely complete writes and initiate a graceful shutdown. Overheating from poor ventilation can cause drives or the NAS to drop out, which also interrupts a rebuild. Low RAM or heavy CPU load can slow or stall the process.
{{UGPRODUCT}}
Software or firmware errors
Outdated or corrupted NAS firmware, file-system issues, or misbehaving apps and containers can trigger rebuild failures. Keeping software current reduces these risks.
How to Troubleshoot a Failed RAID Rebuild
-
Check the replacement drive
Confirm model, capacity, interface, and compatibility. Reseat the drive tray and cables. If the NAS does not recognize the drive, try another bay. If it still fails to appear or keeps dropping, swap in a different drive.
-
Test drive health
Run S.M.A.R.T. short and extended tests on all drives. Replace any disk showing reallocated sectors, pending sectors, high error rates, or repeated read failures. Address marginal drives before retrying the rebuild.
-
Validate RAID configuration
In the NAS manager, confirm the correct RAID level and member order. Clear any foreign or stale configurations. Review error messages on the dashboard and in notifications, then retry the rebuild from the UI if required.
-
Ensure free space and stable file systems
Arrays under extreme capacity pressure are more fragile. Free up space if you are near the limit. Run any vendor-provided file-system checks before restarting a rebuild.
-
Stabilize power and thermals
Plug the NAS into a reliable outlet or UPS. Check UPS batteries and load. Improve airflow, clean dust, and verify all fans spin. Keep the NAS in a cool, ventilated location.
-
Reduce system load
Pause heavy jobs like backups, parity checks, media transcodes, or container tasks. Watch CPU, RAM, and disk I/O in the resource monitor, then restart the rebuild when utilization drops.
-
Update firmware and software
Install the latest NAS firmware, drive firmware if supported, and app updates. Reboot to clear stuck services, then retry the rebuild.
-
Document everything
Note timestamps, error codes, and steps taken. This helps if you escalate to vendor support or a recovery specialist.
Third-Party Data Recovery Tools
If the NAS cannot complete a rebuild, specialized software can sometimes assemble the array virtually and extract files without writing to the original disks.
- EaseUS NAS Data Recovery can virtually reconstruct arrays and recover files without altering the source drives.
- Stellar Data Recovery offers advanced options for complex RAID scenarios.
These tools are paid and can be technical to use. If your data is critical, consider professional recovery services. Avoid actions that write to the disks, such as re-initializing volumes or creating new arrays, until you have a clear plan.

Preventive Actions
-
Back up regularly
RAID is not a backup. Follow the 3-2-1 rule: three copies of your data, on two different types of storage, with one copy off-site or in the cloud.
-
Schedule data scrubbing and S.M.A.R.T. tests
Run monthly S.M.A.R.T. tests and periodic data scrubs to detect and correct silent corruption. Replace drives that show early warning signs.
-
Monitor system health
Review logs and alerts for temperature, read errors, and power events. Track drive age and hours, and replace aging disks proactively.
-
Choose the right RAID level
- RAID 5: Good capacity and speed for home or light office, but only tolerates one drive failure.
- RAID 6: Double parity, tolerates two drive failures, better for large arrays or larger disks.
- RAID 10: Mirroring plus striping, strong performance and resilience, tolerates one failure per mirror pair.
Conclusion
RAID rebuild failures usually trace back to hardware issues, configuration mistakes, power or thermal problems, or outdated software. Work through the basics first: verify drives, confirm settings, stabilize power and cooling, reduce load, and update firmware. If the rebuild still fails, use trusted recovery tools or contact a professional. Solid backups, routine health checks, and the right RAID level will greatly reduce the risk next time.